| Monitoring Location |
Number of Base Flow Sampling Events to Date |
Total Number of Sampling Events to Date |
Average of Base Flow Sampling Events2 (mg/L) |
Grand Average of all Sampling Events (mg/L) |
Range of Values (mg/L) |
Lafayette Road |
1 |
4 |
0.5 |
1.0 |
0.52 - 1.44 |
Davis Road Bridge |
1 |
4 |
0.7 |
1.2 |
0.67 - 1.86 |
McLean Bridge |
1 |
4 |
0.9 |
1.4 |
0.93 - 1.87 |
Freeville |
7 |
18 |
1.0 |
1.1 |
0.44 - 1.69 |
Freese Road |
8 |
19 |
0.8 |
0.9 |
0.10 - 1.66 |
Cayuga Street Bridge |
8 |
19 |
0.7 |
0.8 |
0.02 - 1.71 |
1The NYSDEC standard for class A streams is 10mg/L. For class B, C and D streams, a verbal standard applies: "[No concentration] that will result in growths of algae, weeds, and slime that will impair uses." See Glossary. |
2Average is equal to the sum of n numbers divided by n. Example: Average of 50, 20 and 1000 is 357. |
| Monitoring Location |
Number of Base Flow Sampling Events to Date |
Total Number of Sampling Events to Date |
Average of Base Flow Sampling Events2 (mg/L) |
Grand Average of all Sampling Events (mg/L) |
Range of Values (mg/L) |
Lafayette Road |
1 |
3 |
0.8 |
1.3 |
0.77 - 2.02 |
Davis Road Bridge |
1 |
3 |
1.6 |
2.2 |
1.25 - 3.76 |
McLean Bridge |
1 |
3 |
1.5 |
2.1 |
1.47 - 3.06 |
Freeville |
7 |
17 |
1.4 |
1.7 |
0.95 - 2.65 |
Freese Road |
8 |
18 |
1.2 |
1.5 |
0.55 - 2.47 |
Cayuga Street Bridge |
7 |
17 |
1.2 |
1.6 |
0.66 - 3.29 |
1Total nitrogen is the sum of nitrate-nitrogen, nitrite-nitrogen, ammonia-nitrogen and organic nitrogen. |
2Average is equal to the sum of n numbers divided by n. Example: Average of 50, 20 and 1000 is 357. |
|