Monitoring Location Number of Base Flow Sampling Events to Date Total Number of Sampling Events to Date Average of Base Flow Sampling Events2 (mg/L) Grand Average of all Sampling Events (mg/L) Range of Values (mg/L)
Lafayette Road
1 4 3.3 25.2 2.5 - 92.7
Davis Road Bridge
1 4 3.3 22.6 2.5 - 62.1
McLean Bridge
1 4 4 21.4 2.5 - 73.1
Freeville
7 18 7.4 17.9 2.5 - 61
Freese Road
8 19 6.4 73.9 1.5 - 379
Cayuga Street Bridge
8 19 8.3 97.4 1 - 480
1The NYSDEC standard for suspended solid is verbal: "None from sewage, industrial waste, or other wastes that cause deposition or impair the waters for their best usages."
2Average is equal to the sum of n numbers divided by n. Example: To calculate the average of 50, 20 and 1000, add these numbers and divide by 3: (50+20+1000)/3 = 357.


Monitoring Location Number of Base Flow Sampling Events to Date Total Number of Sampling Events to Date Average of Base Flow Sampling Events2 (mg/L) Grand Average of all Sampling Events (mg/L) Range of Values (mg/L)
Lafayette Road
1 4 1.1 7.1 1.1 - 21.4
Davis Road Bridge
1 4 2.6 13.3 2.2 - 46.1
McLean Bridge
1 4 1.8 15.4 1.8 - 53.2
Freeville
7 18 6.5 12.9 2.6 - 43
Freese Road
8 19 5.7 55 1.7 - 283
Cayuga Street Bridge
8 19 7.6 72.8 3.9 - 378